(see setting description format info here)
Function: | Defines ASCII code of the start character |
Set (S) command format: | SS1ccc, where ccc is the ASCII code of the start character in the 0-255 range |
Post-initialization value: | 0 |
First introduced: | Earlier than "baseline" V3.14/V3.51 |
This setting defines the ASCII code of the start character that can open the serial data block. Start character must be enabled separately through the Use Start Character (F1) setting . Serial data blocks are related to routing the data in the serial-to-Ethernet direction. See serial-to-Ethernet data routing for more information.
Start Character Code is irrelevant when the Start on Any Character (SA) setting is 1 (enabled) because in this case the new serial data block is opened by any character and there is no need to set a specific start character.