(see setting description format info here)
Function: | Defines ASCII code of the stop character |
Set (S) command format: | SE1ccc, where ccc is the ASCII code of the stop character in the 0-255 range |
Post-initialization value: | 0 |
First introduced: | Earlier than "baseline" V3.14/V3.51 |
This setting defines the ASCII code of the stop character that can close the serial data block. The usage of the stop character must be enabled separately through the Use Stop Character (U1) setting . It is also possible to have the serial data block closed not on the stop character itself but after a predefined number of characters after the stop character. This is done through the Number Of Post Characters (P1) setting .
Serial data blocks are related to routing the data in the serial-to-Ethernet direction. See serial-to-Ethernet data routing for more information.