On-the-fly Commands (RC) setting

Description

(see setting description format info here)

Function:Enables or disables on-the-fly command processing by the DS
Set (S) command format:SRCx, where x: 0 (disabled), 1 (enabled)
Get (G) command format:GRC
Init (I) command effect:Initialized unconditionally, through network command, serial command, or quick initialization
Post-initialization value:0 (disabled)
Change takes effect:After reboot
Overriding parameter:---
Relevance conditions:---
First introduced:Earlier than "baseline" V3.14/V3.51
See also:Serial port and serial communications, AuthenticationOn-the-fly (network-side) Parameters and instructions

Details

When On-the-fly Commands setting is 1 (enabled) the DS will accept on-the-fly commands (network-side parameters and instructions) from the network host. When On-the-fly Commands setting is 0 (disabled) the DS will reject on-the-fly commands from the host ( Denied (D) reply code will be returned).

On-the-fly commands do not require prior authentication through Login (L) command . Password protection specifically for on-the-fly commands can be enabled through the On-the-fly Password (OP) setting .

On-the-fly commands provide a way of remotely controlling the serial port of the DS, hence, the name of this setting- "Remote Control".