(see setting description format info here)
Function: | Defines the number of post characters for the stop character |
Set (S) command format: | SP1x, where x: is the number of post characters in the 0-15 range |
Post-initialization value: | 0 |
First introduced: | Earlier than "baseline" V3.14/V3.51 |
Number Of Post Characters defines the number of characters received past the stop character that will still be counted as belonging to the same serial data block. Serial data blocks are related to routing the data in the serial-to-Ethernet direction. See serial-to-Ethernet data routing for more information.
Number of Post Characters is irrelevant when the Use Stop Character (U1) setting is 0 (disabled) because in this case the stop character is disabled.