Flow Control (FC) parameter
Description
(see parameter description format info here)
Function: | Overrides Flow Control (FC) setting |
Parameter (P) cmd format: | PFCx, where x: 0 (disabled), 1 (enabled) |
Possible replies: | A, C, D, R |
Relevance conditions: | current Serial Interface (SI)= 0 (full duplex) |
First introduced: | Earlier than "baseline" V3.14/V3.51 |
See also: | Serial port and serial communications |
Details
Flow Control parameter overrides the Flow Control (FC) setting .
Error (C) reply code is returned if the data supplied in the command is invalid. Denied (D) reply code is returned if:
• | On-the-fly Commands (RC) setting is 0 (disabled). |
• | If no password or incorrect password is supplied while the On-the-fly Password (OP) setting is 1 (enabled) and the password is set (value of the Password (PW) setting is not <NULL>). |
Rejected (R) reply code is returned if this command is sent while the DS is in the serial programming mode .