Function:Overrides Flow Control (FC) setting
Parameter (P) cmd format:PFCx, where x: 0 (disabled), 1 (enabled)
Possible replies:A, C, D, R
Relevance conditions:current Serial Interface (SI)= 0 (full duplex)
First introduced:Earlier than "baseline" V3.14/V3.51
See also:Serial port and serial communications

Details

Flow Control parameter overrides the Flow Control (FC) setting .

Error (C) reply code is returned if the data supplied in the command is invalid. Denied (D) reply code is returned if:

On-the-fly Commands (RC) setting is 0 (disabled).
If no password or incorrect password is supplied while the On-the-fly Password (OP) setting is 1 (enabled) and the password is set (value of the Password (PW) setting is not <NULL>).

Rejected (R) reply code is returned if this command is sent while the DS is in the serial programming mode