DTR Startup Mode (DS) setting

Description

(see setting description format info here)

Function:Defines High or Low state of DTR pin on Startup 
Set (S) command format:SDSx, where x: 0 (LOW* on startup), 1 (HIGH* on startup)
Get (G) command format:GDS
Init (I) command effect:Initialized unconditionally, through network command, serial command, or quick initialization
Post-initialization value:0
Change takes effect:After reboot or exiting the serial programming mode
Overriding parameter:---
Relevance conditions:DTR Mode (DT) setting = 0 (idle)
First introduced:V3.27/V3.57
See also:Serial programming

Details

This setting defines the startup voltage of the DTR pin. By default, DTR is LOW* on startup. By changing this setting, you can have DTR set to HIGH* on startup.

DTR Startup Mode is irrelevant when the DTR Mode (DT) setting is 1 (connection status).

* HIGH and LOW states are described with respect to the serial ports of DS100R, DS100B, DS203. For EM100, EM120, EM200, EM203(A) the signaling is exactly opposite.