Sock.Endchar Property

Function:

For the currently selected socket (selection is made through sock.num) specifies the ASCII code of the character that will end inband command (message).

Type:

Byte

Value Range:

0-255, default= 13 (CR)

See Also:

sock.escchar

Details

Each inband message has to end with the end character, which will mark a return to the "regular" data stream of the TCP connection.

This property is irrelevant when inband commands are disabled (sock.inbandcommands = 0- NO). The program won't be able to change the value of this property when the socket is not idle (sock.statesimple <> 0- PL_SSTS_CLOSED).