Ordering Info and Specifications
The device numbering scheme for the EM1001 is as follows:
Hardware Specifications
Ethernet interface |
10/100BaseT Ethernet, Auto-MDIX, with RJ45/magnetics |
Serial ports |
Four ports, CMOS-level |
UART capabilities |
Baudrates up to 921,600bps; none/even/odd/mark/space parity and 7/8 bits/character |
Number of I/O lines |
54 lines (including five on the wireless add-on connector); all lines are 5V-tolerant; 40 of I/O lines are combined into five 8-bit ports; eight lines can be used as interrupt lines. |
Max. load current for each I/O line |
10mA |
Square wave generator |
6Hz ~ 22.1184MHz, primarily intended for driving an external buzzer |
Real-time counter (RTC) |
40 bit, increments at 128Hz |
RTC backup power source ("-S" version only) |
Supercapacitor, supports RTC for approximately six days |
Clock frequency |
|
Flash memory |
1,024KB, the entire memory minus 64KB is available for storing Tibbo BASIC/C application and data. Typical write endurance is 100,000 write cycles per 256-byte sector. See the warning in Flash Memory and EEPROM. |
EEPROM |
2,048 bytes, 2,020 bytes available for storing application data. Typical write endurance is around 1,000,000 write cycles per 16-byte EEPROM sector. See Prolonging and Estimating EEPROM life. |
Switching regulator supply voltage (supplied via the power jack or VIN pin) |
Unregulated, 8V~20V input range, 12V nominal |
Direct system power (supplied via the 3.3V pin bypassing the switching regulator) |
Regulated, 3.3V ±10% |
Available current on the 3.3V pin (when powering through the voltage regulator) |
|
Reset circuit trip voltage (VCC pin) |
|
Operating current when the 3.3V is supplied directly through the 3.3V pin |
|
Operating temperature |
–20°C to +80°C |
Operating relative humidity |
10% ~ 90% |
Mechanical dimensions (excluding RJ45 and power jack) |
|