.Currentpll R/O Property (Selected Platforms Only)

Top  Previous  Next

 

Function:

Returns current PLL mode of the device

Type:

Enum (no_yes, byte)

Value Range:

0- NO: PLL is off, the device runs at low speed with reduced power consumption.

1- YES: PLL is on, the device runs at maximum speed, x8 faster than low speed.

See Also:

sys.newpll

 


Details

After the external reset the device typically boots with PLL on. You can switch PLL off and on programmatically by using the sys.newpll method and then "self-resetting" the device using the sys.reboot method.

Actual PLL mode change only takes place after you "self-reset" the device using sys.reboot method or the device self-resets due to some other reason (for instance, there is a self reset after a new BASIC application upload, or when you hit "restart" button in TIDE). External resets- power-up and RST pin reset (reset button reset)- set the PLL to default state (typically ON). On some devices there is a hardware jumper that defines the post-external reset state of the PLL.

Not all Tibbo devices have PLL- to find out if yours does, refer to its platform documentation (for example, EM1000's is here).