Link Service Login (TL) setting

Top  Previous  Next

 

Description (see setting description format info here)

 

Function:Enables/disables Link Service login procedure after a TCP data connection is established

 

Set (S) command format:STLx, where x: 0 (disabled), 1 (enabled)

 

Get (G) command format:GTL

 

Init (I) command effect:Initialized unconditionally, through network command, serial command, or quick initialization

 

Post-initialization value:0 (disabled)

 

Change takes effect:After reboot

 

Overriding parameter:---

 

Relevance conditions:Current Transport Protocol (TP) [setting/parameter]= 1 (TCP)

 

First introduced:V3.24/3.54

 

See also:Ethernet port and network communications, Link Service

 


Details

 

This setting defines whether the DS will perform Link Service login procedure after a TCP data connection with another network host is established. For more information on Link Service see Link Server Documentation.

 

Link Service logins use the data from the following settings of the DS: Owner Name (ON), Device Name (DN), and Password (PW) setting). The password is supplied in the encrypted form so Link Service logins are secure.

 